Aeotec Home Energy Meter Gen5, Z-Wave Plus Smart Electricity Usage Monitor, Report Real Time Power Consumption, 1 Clamp, Detect up to 60 amps for Single Phase System

£54.995£109.99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

The unit was a set of clamps and a separate display which I connected up to a PC program for logging purposes. The idea is we must calibrate the sensor by telling it how much current was really going through the cable when it was reporting a specific value.

Safe and Simple Installation: Our energy monitor doesn't require any wire connections to be changed for installation. EDIT: I realised solar should be unaffected since the current flow from the intverted is not influenced by the house load. Paired with your Z-Wave gateway, it’ll help you diagnose which electronics in your home are costing you the most. Again, I can understand that moving the CT might cause a slight change especially if the two halves of the core moved and added, altered or removed a small air gap, but I cannot see how that could repeat on alternate readings. I could not get the lower amperage CT clamp at the time, and if necessary I can get another one, but at the same time I don’t see why it should not work to some degree.The clamp wasnt able to go over the incoming power cable whilst the cable still had its grey outer sheath on.

The last one from above is probably causing some “noise” that is slightly off phase from the measured current, so sometimes reads higher and sometimes reads lower depending on the point of the phase where the measurement is taken. The clamp detects one load / circuit and reports the real-time power consumption to your Z-Wave smart home control gateway. It is available with optional clamps from 80A all the way up to 500A for some industrial applications.This means that it will not show any usage if you switch on only -for example- a led light of 9 Watt. They could be noise from something switching, and it was just chance that the pulses are at half your logging frequency.

I have used (and therefore only tested) a basic configuration of report clamp 1 in group 1, clamp 2 in group 2, and clamp 3 in group 3. Z-Wave Plus Aeotec Clamp Power Meter - Three Clamps (60A) includes the following technologies, which means it should work fine with other devices using the same technology. It worked - sort of, but was not accurate and picking up noise which sent the numbers all over the place. However, I’ve never seen these clamps on installation photos (even with expensive, brand ones) or live installed as a tight fit nor on a completely straight cable or far from other cables - on the contrary! I don’t have much experience with CTs and I found no specific instructions as how to put the meter on the wire.You need something else - a hub or a controller for example - to save and display your electricity consumption readings. You need to have owner-level access on your portal, so you’re are able to download CSV sheets for your daily instantaneous power data for the inverter. The Sunny Home Manager is the ideal solution for simple plant monitoring and intelligent energy management.