About this deal
Compatible with aroTHERM air-to-water heat pump hybrid system – Making the perfect entry into renewable systems The pressure relief valve could also be letting by. Or, the filling loop on the Vaillant boiler could be slightly open or damaged. Do I need to turn my boiler off to repressurise? The pressure on a Vaillant boiler should be between 1 and 1.5 bar when the central heating is off and the radiators are cold. Correct Vaillant boiler pressure Removable side panels and push-fit flue system – For improved accessibility, ease of installation and greater installation flexibility
A filling loop will be built in on the bottom of your boiler on most modern and small combi boilers, but there could also be an external filling loop on the pipework. Our boiler seems to run with little pressure so it may have been low for quite a while during the summer. The hot water on reflection wasn't as hot as it is once the pressure is topped up, which makes me think it has been like it a while. I've not been topping it up at all during the summer but last winter I had to top it up fairly frequently when we were using the heating - every 3-4 days maybe. I thought it was a slow leak. Compatible with aroTHERM air-to-water heat pump hybrid system - Making the perfect entry into renewable systems You should see a schraeder valve on it - don't let the name panic you it looks just like the ones that you pump your car tyres up withA leak could be anywhere on the full system, boiler, radiators, or pipework under floors. Leaking radiator valve You can do this via a drain-off valve. A drain-off valve can be on the boiler, a radiator valve or anywhere on the central heating pipework. Radiator drain off valve Another cause could be the expansion vessel has lost its air and needs to be recharged or replaced. Yes. You can repressurise a Vaillant boiler by yourself, and you should definitely learn how to repressurise a combi boiler if you don’t already know. Can someone kindly explain what are the key indicators are that my combination boiler expansion vessel needs to be replaced?
This is usually below the boiler but there could be an external flexible filling loop anywhere on the system, sometimes hidden away in cupboards or behind boxing. Total system solution available from one manufacturer – Intelligent controls and accessories availableIf you need to repressurise your Vaillant boiler once or twice a year I wouldn’t worry about it as it’s such a small leak that it’s barely noticeable. There should be one of these types of boiler filling loops under your Vaillant combi boiler, if not then it will be an external filling loop. Vaillant boiler filling loop closed This is a common fault on Vaillant Ecotec boilers and is caused by the expansion vessel losing its charge.